Insulation R Value Savings
Calculator
Results
- Annual heat loss before (kWh/yr)
- 3,199.999999
- Annual heat loss after (kWh/yr)
- 1,066.666666
- Annual energy saved (kWh/yr)
- 2,133.333333
Energy results
| Annual heat loss before (kWh/yr) | 3,199.999999 |
| Annual heat loss after (kWh/yr) | 1,066.666666 |
| Annual energy saved (kWh/yr) | 2,133.333333 |
formula-map diagram
- Annual heat loss before (kWh/yr)
- 3,199.999999
- Annual heat loss after (kWh/yr)
- 1,066.666666
- Annual energy saved (kWh/yr)
- 2,133.333333
Energy relationship
Formula
Q(kWh/yr) = A × (1÷R) × HDD × 24 ÷ 1000, compared before/after R-value= 3200
Note
This is a simplified model: it applies the standard equation to the numbers you entered and ignores real-world losses, weather variation, tariff structures and equipment tolerances. Wind power assumes air density 1.225 kg/m³ at ISA sea level and the power coefficient you enter (Betz limit 0.593). Verify with measured data or a professional energy audit before making purchasing decisions.
Example: with the default inputs, calculator.energy.annual_loss_before_kwh is 3199.9999999999995.
More in Energy and environment
See all →Frequently asked questions
How does the calculator estimate heat-loss savings from insulation?+
For each R-value it computes annual loss as area × (1 ÷ R) × heating degree-days × 24 ÷ 1,000, in kWh. The saving is the loss before minus the loss after.
What unit is the R-value in?+
The fields use m²·K/W, so a higher R-value means better insulation. Do not enter values in imperial units, as the formula would then give wrong results.
What are heating degree-days?+
They are the yearly total you enter (default 2,000), which stands in for how cold your climate is. The calculator does not look it up for your location.
Does the result include air leaks, windows or the cost of insulation?+
No. It only covers conduction through the insulated area you enter, using a simple steady-state formula. Air leakage, other surfaces and installation costs are not included.
Will I save exactly this much energy?+
Not necessarily. The result is an estimate of heat loss in kWh per year, not a guaranteed saving or professional advice. Real results depend on the building and how it is used.