Geothermal Heat Pump Savings
Calculator

Inputs

Heat pump electricity used (kWh)
3,157.894736

Results

Heat pump electricity used (kWh)
3,157.894736
Resistance heating electricity used (kWh)
12,000
Heat pump annual cost
505.263157
Resistance heating annual cost
1,920
Annual savings
1,414.736842

Energy results

Heat pump electricity used (kWh)3,157.894736
Resistance heating electricity used (kWh)12,000
Heat pump annual cost505.263157
Resistance heating annual cost1,920
Annual savings1,414.736842

formula-map diagram

Heat pump electricity used (kWh)
3,157.894736
Resistance heating electricity used (kWh)
12,000
Heat pump annual cost
505.263157
Resistance heating annual cost
1,920
Annual savings
1,414.736842

Energy relationship

Formula

Electric input(kWh) = heat delivered(kWh) ÷ COP (or ÷ efficiency for resistance)

= 3157.8947368421

Note

This is a simplified model: it applies the standard equation to the numbers you entered and ignores real-world losses, weather variation, tariff structures and equipment tolerances. Wind power assumes air density 1.225 kg/m³ at ISA sea level and the power coefficient you enter (Betz limit 0.593). Verify with measured data or a professional energy audit before making purchasing decisions.

Example: with the default inputs, calculator.energy.heat_pump_electric_kwh is 3157.8947368421054.

More in Energy and environment

See all →

Frequently asked questions

How are heat pump savings calculated?+

The calculator divides the annual heat you need by the heat pump COP to get its electricity use, and by the resistance heater efficiency to get the resistance electricity use. Savings are the difference between the two, multiplied by your electricity rate.

What does COP mean in this calculator?+

COP is the ratio of heat delivered to electricity consumed. A COP of 3.8 means 3.8 kWh of heat for each 1 kWh of electricity, and you enter the value yourself.

What is the resistance heating efficiency input for?+

It sets the baseline you compare against. At 100 percent, every kWh of electricity becomes one kWh of heat; a lower value means more electricity is needed for the same heat.

Should the annual heating need be thermal or electrical kWh?+

Enter the heat delivered to the building, in thermal kWh. The calculator converts it into electricity for each system itself.

Does it account for installation cost or a year-round average COP?+

No. It uses the single COP you enter and compares only annual electricity cost. Installation cost, payback, maintenance and seasonal COP variation are not included, so treat the result as an estimate.